Home » Products Showcase » SMART POWER SYSTEM TRAINER
Description
Salient Features
- XPO-SPS is an operations practice trainer consisting of 8 tables, 4 RTUs, and 4 setups integrated through SCADA software. It cannot be purchased in parts.
- Designed to develop a real-time automated power system network and control test-bed at laboratory level.
- Provides experiments and analysis to help students understand power system engineering fundamentals and smart grid implementation.
- The system includes four power engineering setups:
- Generation
- Synchronisation
- Double Bus Bar
- Transmission & Distribution
- Integrated with numeric protection relays, including:
- Generator protection
- Synchronisation relay
- Distance protection
- Transformer protection
- Includes:
- RTUs with Ethernet and RS485/MODBUS ports
- Touch panel HMIs
- SCADA supervisory controller
- Patch cords and aluminum profile tables.
- Optional add-ons:
- Second generating station using three-phase alternator
- DFIG wind power simulation
- Solar grid-tied system
- Useful for:
- Undergraduate practicals
- Postgraduate projects
- Research applications.
Technical Specifications
1. SCADA Components
PCs
- 4th generation Intel Core
- 2.9 GHz dual-core
- Windows 8.1
- 8 GB RAM
- 500 GB HDD
- 4 units
Supervisor Station
- Touch panel PC with 8-port Ethernet switch
Local Stations (HMI)
- Touch panel PCs near RTU units
- 3 units
UPS
- 500VA / 30-minute backup
- 4 units
Software
Multi-drop SCADA software supporting screens such as:
- Generator control panel
- Synchronization screen
- Generator differential protection relay screen
- Load selection screen
- Double bus bar screen
- Transmission line screen
- Fault simulation screens
- Distance protection screen
- Transformer differential protection screen
- Power measurement screen
- Alarm & event management.
RTUs
Rack with 3×1 panels including:
- PLC with 48 I/O (24 inputs + 24 outputs)
- RS485 Modbus interface
- Ethernet interface
- Relay output cards.
IEDs
Multifunction Meters
Measure:
- Voltage
- Current
- Power factor
- Frequency
- Watts
- VAR
- Energy
Quantity: 15
Phase Angle Measurement Meters
2 units
Protection Relays
4 units
Types:
- Generator protection relay
- Distance protection relay
- Transformer differential protection relay
- Automatic synchronization relay.
Variable Frequency Drive
- 7 kW VFD
- RS485 Modbus communication
- Analog inputs for frequency synchronization and excitation control.
Power Engineering Stations
- Generation trainer
- Synchronization trainer
- Transmission & Distribution trainer
- Double Bus Bar trainer
Transformers
Generator Transformer
- 3-phase
- 3–5 kVA
- YY11 connection
Grid Transformer
- 3-phase
- 5 kVA
- YY11 connection
Distribution Transformer
- 3-phase
- 3 kVA
- YY11 phasor group.
Accessories
RTU Tables
- Aluminum profile frame
- Rubber wood / Nova pan table top
- Lockable drawers
- Castor wheels with locking
- Size: 1200 × 750 × 760 mm
Cables
Includes:
- 9-pin D cables (21)
- 37-pin patch cables (3)
- 3-phase power extension cables (3)
- RS485 patch cables (22)
List of Experiments
- Manual & automatic generator synchronization with grid
- V-curve and inverted V-curve study
- Generator performance analysis
- Generator protection studies
- Voltage variation and control
- Voltage regulation study
- 3-bus load flow study
- Ferranti effect study
- Transmission line efficiency and regulation
- Short transmission line model study
- Fault analysis on transmission line
- Distance protection study
- Auto-reclose function study
- Distribution transformer protection study
- 4-bus load flow study
Total Weight: 1.8 tons
Volume Weight: 3.6 tons.

other educational working models and laboratory kits to enhance hands-on learning in engineering and technical laboratories. In addition, institutions may also explore complementary learning solutions such as Jaadui Pitara educational learning kits to support interactive and concept-based education.